Confirmed on the employer's own hiring board on Nov 18, 2026. First seen by Alion on Nov 18, 2026. Archirodon scores A on the Alion truth index.
Archirodon, having earned its reputation as a reliable and respected international contractor for more than a half century in the Engineering, Procurement and Construction (EPC) market, continues to create value to its stakeholders by executing complex EPC projects worldwide, in recognition of its superior standards of performance.
We have an outstanding record in completing major Energy (Oil & Gas - Power and Water), Marine, Infrastructure and Defense & Security projects around the globe and we pride ourselves on delivering over the years the kind of reliability and trust that the client has the right to expect from a major EPC contractor.
Key Responsibilities
- Prepare and review commissioning procedures, test plans, checklists, and inspection and test records for impressed current and galvanic anode CP systems.
- Verify installation and readiness of transformer rectifiers, anode beds, junction boxes, test stations, reference electrodes, and associated cables against approved drawings.
- Perform and witness pre-commissioning checks, including cable continuity and insulation resistance, polarity verification, anode bed resistance, and baseline structure-to-electrolyte potential measurements.
- Energize and adjust transformer rectifiers, measure current output and protection potentials, and verify performance against project acceptance criteria.
- Carry out ON and instant-OFF potential measurements, close-interval potential surveys (CIPS), and interference testing where required by the project.
- Troubleshoot issues such as low protection levels, stray current interference, cable faults, and rectifier failures. Coordinate corrective work and retesting.
- Coordinate commissioning activities and client witness inspections with construction, QA/QC, HSE, vendors, and operations teams.
- Close commissioning punch items and prepare test reports, baseline readings, and handover dossiers.
- Ensure all field activities comply with site HSE requirements, permit-to-work procedures, and electrical isolation requirements.
Knowledge & Skills:
- Bachelor’s degree in Electrical, Materials, Corrosion, or a related engineering discipline.
- Minimum 5 years of relevant experience in cathodic protection, including hands-on commissioning of CP systems on oil and gas projects.
- Practical experience with both impressed current and galvanic anode systems, including field measurements, troubleshooting, and client handover.
- Ability to interpret CP layouts, wiring diagrams, design calculations, and project specifications.
- Familiarity with applicable AMPP and ISO standards and client specifications.
- AMPP CP2 (Cathodic Protection Technician) certification or higher is preferred.
- ADNOC project experience is an advantage.
IT / Software Skills:
- Proficient in MS Office, Electrical Testing Tools (OMICRON/Doble software), and CMS/Commissioning tracking systems.
- Basic knowledge of AutoCAD for red-line updates is beneficial.
Languages:
- English - Full Professional Proficiency.
Qualifications & Experience:
- Bachelor’s degree in electrical engineering from a recognized university.
- ADNOC-approved or equivalent certification in commissioning or HV/LV safety will be an advantage.
- Recognized training in Electrical Safety, Lockout-Tagout (LOTO), and PTW systems preferred.
- Essential: Minimum 10-12 years ’ experience in electrical commissioning within Oil & Gas, Power Generation, or Petrochemical projects.
- Experience with EPC or PMC contractors under ADNOC, QP, or Aramco projects preferred.
- Proven background in field execution, system energization, and documentation control.