2,326,162open jobs
146,540companies
276,824added this week
Browse all
Location
Hybrid (United States)
Seniority
Architect · 12+ years exp
Employment
Full-Time

Confirmed on the employer's own hiring board on Nov 17, 2026. First seen by Alion on Nov 16, 2026.

Overview
Company
Impact
Profile match

PIC

PIC engineers and delivers the infrastructure the AI era runs on: power, land, construction, networking and software, as one company.
Backed by Frst

About the role

Most senior mechanical jobs in this industry stop at the building line. Water shows up, sewer takes it away, and someone else owns all of that. At PIC, we pick our sites for power and land, which means they usually arrive without the water or sewer a campus needs. So alongside the cooling work you would expect, you will own water source development and treatment, cooling water chemistry and reuse, wastewater treatment and discharge, and a centralized fire water system we store and pump ourselves.

This role is our senior technical authority for mechanical systems across the portfolio: cooling topology and heat rejection, air and water distribution, liquid cooling, and the plant that makes a datacenter actually run. It also puts both sides of the utility boundary in one set of hands, which is rare, and which is the whole point. You will set the design basis, choose the approach, direct the consultants who engineer it, and defend the result to regulators, AHJs, and the operations team that has to live with it.

What you’ll do

Mechanical and cooling basis of design

  • Own the mechanical basis of design for the portfolio: cooling topology, chilled and condenser water systems, heat rejection selection, air distribution and containment, humidity and ventilation strategy, and the redundancy scheme behind our availability and concurrent maintainability targets

  • Call the technical approach for high-density and liquid-cooled deployments, including CDU selection, secondary loop water quality and chemistry, filtration, and the facility water interface to IT equipment

  • Size the plant; N+1 or 2N configuration, part-load performance, and the operating strategy operations inherits, failure modes and manual operation included

  • Cover the support systems: generator and UPS room cooling, battery room ventilation and thermal management, electrical room cooling, fuel system mechanical scope, and general building HVAC

  • Set the numbers the design gets judged against; PUE and WUE at design and part load, approach temperatures, and the total cost of ownership case behind the topology you picked, then hold the consultant’s design to them

Water supply and treatment

  • Build the water strategy for each campus: source and sustainable yield, whether municipal, groundwater, surface, reclaimed, or non-potable; raw water characterization; and the treatment train that serves cooling, humidification, potable, and fire water demand

  • Set the process design basis for treatment: pretreatment, filtration, softening, reverse osmosis, demineralization, disinfection, and size storage, pumping, and redundancy to the site’s availability class

  • Own cooling water chemistry: cycles of concentration strategy, side-stream filtration, scaling and corrosion control, the biocide program, and Legionella risk management plan design; hand operations limits they can actually hold

  • Push reuse and conservation: blowdown recovery, condensate capture, reclaimed water integration, and weigh closed-loop and reduced-evaporation options against water use effectiveness, capital cost, energy penalty, and permitting risk. Reclaimed and non-potable mandates are becoming a condition of approval in several of our target markets

Wastewater and discharge

  • Set the wastewater strategy where municipal sewer is missing or maxed out: characterization, on-site treatment selection, and the call between surface discharge, land application, subsurface disposal, and haul-off; each one carries its own permitting path and schedule risk

  • Define how cooling tower blowdown gets handled: total dissolved solids, temperature, pH, biocide residual, and flag any constituent of concern that will drive permit conditions or monitoring

  • Own the technical content behind discharge permitting, including NPDES or the state-delegated equivalent, industrial pretreatment agreements, and groundwater and land application permits; carry environmental counsel and consultants through it with engineering that holds up

  • Design monitoring and reporting in from day one: sampling points, continuous monitoring instrumentation, and the data path to compliance reporting. Retrofitting that after a permit lands is the expensive way to do it

Centralized fire water

  • Own the campus fire water concept end to end: demand across every protected occupancy, storage volume and tank configuration, fire pump selection and arrangement, redundancy, looped distribution, hydrant and fire department connection layout, and freeze and stagnation management

  • Build the design basis against NFPA 20, 22, 24, 25, 75, and 855 plus the applicable IFC and IBC provisions, and settle it with the AHJ early rather than at plan review

  • Own the handoffs to building fire protection design and to battery energy storage suppression and deflagration requirements, along with the inspection, testing, and maintenance regime

  • Reconcile fire water storage against process and cooling water storage, so the campus is not paying twice for the same volume and the fire reserve stays genuinely protected

Campus utilities planning

  • Own the underground and yard utility master plan: domestic water, fire water, process water, wastewater, condensate, and natural gas or liquid fuel, plus corridors, easements, separations, and phasing

  • Set the design basis for fuel storage and delivery to on-site generation, including containment, transfer, polishing, and refueling logistics at remote sites

  • Reconcile the utility master plan against the mechanical plant it serves. You own both sides of that boundary, so make-up water, blowdown, condensate, storage, and heat rejection capacity have to agree at every phase. In writing, not by assumption

  • Work with civil, electrical, structural, and controls so utility routing, tank foundations, pump power, and instrumentation get resolved before they turn into field conflicts

Be the technical authority

  • Write the scopes for mechanical, process, civil, and utility consultants, review and approve what they deliver, and be the approval a design needs before it issues

  • Run or direct independent verification: hydraulic modeling, mass and water balance, storage sizing, redundancy analysis, and life-cycle cost comparison of alternatives

  • Back procurement on treatment skids, pumps, tanks, and packaged systems through specification, bid evaluation, and factory witness testing

  • Back operations through startup, commissioning, operator training content, and a documented operating envelope for every system you set

About you

  • 12+ years in mechanical systems design or delivery for data centers, industrial, or heavy process facilities, operating as the technical authority rather than in a production seat

  • Real depth and ownership in industrial water treatment, wastewater treatment, and fire water systems

  • At least one industrial or municipal-scale water treatment system and one wastewater treatment or discharge solution that you carried from concept through startup

  • Command of data center cooling topologies: chilled water, condenser water, air-cooled and evaporative heat rejection, and liquid cooling, and a point of view on where each belongs and what it costs over its life

  • Working command of NFPA 20, 22, 24, and 25; you can build a fire water demand and storage calculation and defend it in front of an AHJ

  • Direct experience with discharge permitting and regulatory interaction, such as NPDES or the state-delegated equivalent, industrial pretreatment, or groundwater permitting

  • Hydraulic modeling capability, and the judgment to notice when a model is confidently telling you something wrong

  • A bachelor’s degree in mechanical, chemical, civil, or environmental engineering

Nice-to-haves

  • PE licensure

  • Data center, semiconductor, power generation, pharmaceutical, or heavy process industry experience where cooling water is a first-order design constraint

  • Experience in water-constrained or arid markets, or with projects subject to reclaimed water or net-zero-water conditions of approval

  • Familiarity with ASHRAE thermal guidelines for data processing environments and current liquid cooling practice, including where the standards have not caught up to what is being deployed

  • Startup, first-of-a-kind, or greenfield experience where nothing existing could be assumed and the design basis had to be written from nothing

Additional requirements

  • 20 to 30% travel, weighted toward site diligence, regulatory and AHJ meetings, and commissioning

  • Field work investigating water sources, existing utility tie-ins, and treatment equipment; expect outdoor work in all conditions, elevated and confined-space-adjacent areas, and active construction sites with required PPE and safety training

  • In-person meetings with AHJs, utilities, and state environmental agencies in the jurisdictions where we develop. These are rarely resolvable by video and they often decide the schedule

  • Vendor factory visits and witness testing for treatment skids, fire pumps, and packaged systems

  • On-site presence during startup and commissioning of water and fire water systems, including work outside normal hours and during scheduled outage windows

Free account
Stop reading job ads. Get the ones that fit.
One free account turns this page into a shortlist built around your stack, your level and your pay.
Match on every job. Stack, seniority, pay and location, scored against your profile.
2,326,162 open roles. Read straight off company career pages, refreshed every day.
Unlimited applications. Every one you send is tracked in one place, on-site or on a company board.
3 tailored CVs a month. Rewritten for the exact job you are applying to. Included free.
Create a free account Continue with Google
Free forever. No card. Under a minute.

Recommended for you based on this role

Industrial Engineering
Remote, many countries
Similar stack
Same company
United States
$64k – $110k per year · In office · 10+ years exp · Associate's Degree · Durham
Apply
Equity · In office · Full-Time · 10+ years exp · High School Diploma · Hubbard
Apply
Equity · In office · Full-Time · 10+ years exp · United States
Apply
$136k – $180k per year · Equity · In office · Full-Time · 5+ years exp · Bachelor's Degree · Pleasanton
Design
SolidWorks
SpaceTech
FMEA
Life Sciences
Design of Experiments
MedTech
Verification & Validation
Apply
In office · High School Diploma · Edgerton
Life Sciences
GMP
Apply
Remote (EAEU) · 5+ years exp · Yekaterinburg
Design
AutoCAD
Apply
Remote (EAEU) · 7+ years exp · Bachelor's Degree · Moscow
Design
AutoCAD
Apply
$14k per year · Remote (EAEU) · 2+ years exp · Moscow
Design
AutoCAD
Apply
$20k per year · Remote (EAEU) · Volgograd
Apply
$20k per year · Remote (EAEU) · Krasnodar
Apply
≈ $74k – $136k per year (Estimated) · In office · Full-Time · 4+ years exp · Bachelor's Degree · United States
DevOps
Windows
Analytics
Microsoft Excel
Apply
$138k – $207k per year · In office · Full-Time · 7+ years exp · Philadelphia · Englewood
Python
Go
Bash
DevOps
Rest API
Ansible
CI/CD
GitOps
Git
Configuration Management
Linux
Unix
TCP/IP
DNS
BGP
Apply
In office · Part-Time · 1+ year exp · Bachelor's Degree · Tempe · Chandler
Apply
In office · Full-Time · High School Diploma · Phoenix · Scottsdale
Apply
$52k – $78k per year · In office · Full-Time · 2+ years exp · Associate's Degree · United States
Apply
See all jobs
This is one of many
2,326,162 more open roles from verified company boards, updated every day.